BS 8592:2016 pdf free.Electric cables – Thermosetting insulated, non-armoured, fire-resistant, single core non-sheathed cables of rated voltage 450/750 V, having low emission of smoke and corrosive gases when affected by fire – Specification.
BS 8592 This British Standard specifies requirements and test methods for the construction and performance of non-armoured, single core non-sheathed cables which:
a) have a thermosetting insulation of rated voltage 4501750 V;
b) provide resistance to fire (circuit integrity), including mechanical shock, as measured by performance in a standard test;
c) emit limited amounts of smoke and corrosive gases when burned as measured by a standard test;
d) are flame retardant; and
e) are primarily, but not exclusively, intended for use inside metal enclosures such as steel conduit.
This British Standard is applicable to cables for use in fixed installations in industrial areas, buildings and similar applications, where maintenance of power supply during a fire is required for a defined period of time.
NOTE 1 Attention is drawn to the fact that the ability of a given cable to meet the test in this standard refers only to the test conditions stated, and the level of performance achieved in a particular installation can be influenced by actual installation conditions.
The insulation and other components are suitable to permit operation of the cables at a maximum sustained conductor temperature of 90 °C and for a maximum short-circuit conductor temperature of 250 C (for a maximum of 5 s).
NOTE 2 Annex A gives recommendations for the selection, installation and operation of cables. Annex B gives notes on type tests.
Normative references
The following documents, in whole or in part, are normatively referenced in this document and are indispensable for its application. For dated references, only the edition cited applies. For undated references, the latest edition of the referenced document (including any amendments) applies.
BS EN 50363-5, Insulating, sheathing and covering materials for low voltage energy cables — Part 5: Halogen-free, cross-linked insulating compounds
BS EN 50395, Electrical test methods for low voltage energy cables
BS EN 50396, Non electrical test methods for low voltage energy cables
BS EN 60228, Conductors of insulated cables
BS EN 60332-1-2:2004+A1:2015, Tests on electric and optical fibre cables under fire conditions — Part 1-2: Test for vertical flame propagation for a single insulated wire or cable – Procedure for 1 kW pre-mixed flame.BS 8592 pdf download.

Download infomation Go to download
Note: Can you help me share this website on your Facebook or others? Many thanks!
BS ISO 7425-1:2021 pdf free Free BS Standards

BS ISO 7425-1:2021 pdf free

BS ISO 7425-1:2021 pdf free.Hydraulic fluid power cylinders一Dimensions and tolerances of housings for elastomer- energized, plastic-faced seals Part 1: Piston seal housings. 5.2 Axial length For axial lengths for the nominal piston diameters, see Iable3. If the...
Get More
BS EN ISO 8407-2021 pdf free download Free BS Standards

BS EN ISO 8407-2021 pdf free download

BS EN ISO 8407-2021 pdf free download.Corrosion of metals and alloys一Removal of corrosion products from corrosion test specimens. 4.1.6 The true mass of the specimen, after removal of the corrosion products, will be a value between the...
Get More

LEAVE A REPLY

Anonymous netizen Fill in information